ULTRASONIC SENSORS
Air Ultrasonic Transducers radiate ultrasonic waves into the air and sense
the reflected waves from objects within the radiation field to detect them or measure
their distance.
Fuji & Co. offers
this sensor:
| FUS - 40B, closed face and excellent for harsh
environmental conditions.
|
Features:
| High Sensitivity
|
| Small size and light weight
|
| Closed face construction for high humidity protection.
|
Applications:
| Distance measurement
|
| Monitoring uses for level of substance in a tank
|
| Automatic door openers and security alarms
|
| Proximity switches for FA system
|
Construction and Dimensions:
Type |
FUS - 40BT/R
T=Transmitter R=Receiver |
Construction |
Closed face |
Nominal Frequency |
40 kHz. |
Dimensions |
|
Specifications:
Type |
FUS - 40BT
Closed type transmitter |
FUS - 40BR
Closed type receiver |
Nominal Frequency |
40KHz. |
Sound Pressure Level
Sensitivity |
105 dB min
(0dB = 2 X 10 -5 Pa) |
-57 dB min
(0dB = 1V/Pa) |
Bandwidth |
2 kHz. min.
(100 dB) |
2 kHz. min.
(-60dB) |
Electrostatic Capacity |
2600 pF +/- 20% |
Radiation Directivity |
80 degrees |
80 degrees |
Max Input Voltage |
|
|
Operating Temp Range |
-20 ~ 70 degrees C |
Storage Temp Range |
-35 ~ 80 degrees C |
Measurement Circuit, Transmitter |
|
Measurement Circuit, Receiver |
|
Environmental Characteristics:
Storage at high temperature |
80 deg C, 500 hours |
Variation of Sensitivity:
within 3 dB |
Storage at low temperature |
-35 deg C, 500 hours |
Durability, humidity |
60 deg C, 90 ~ 95% RH, 500 hours |
Durability, long operation |
60 deg C, 85% RH, 10V rms, 500 hours |
Shock |
3 drops 1m onto hard wood plate |
Vibration |
10-55-10 Hz / 1 minute
Amplitude 1,5mm
X, Y, Z each 1 hour |
|