The DLATGS element is used for detection when
extreme sensitivity is required that cannot be achieved using normal PZT
sensors. The DLATGS element has 5 to 8 times the sensitivity of PZT.
The FTS110CA has a 4.35µm bandpass filter well suited for long range flame and gas
(CO2) detection.
|
|
Model
FTS110CA |
Values |
Unit |
Condition |
Element size |
1.5 dia. |
mm |
|
Signal Sensitivity |
typ. 34 |
mV p-p |
500K, 1Hz |
Noise |
typ. 250 |
mV p-p |
25°C, x5000 |
Source voltage |
0.38 ~ 1.3 |
V |
25°C |
Supply voltage |
2.0 ~ 10 |
V |
|
Load resistor |
10 ~ 1,000 |
kOhm |
|
Operating temp. |
-10 ~ 40 |
°C |
|
Notes: |
| The sensor is better adapted where ambient temperature variation
is small. |
|
|
| Because of usage, a constant temperature environment is
recommended. |
|
|
| Operation at ambient temperatures above 40°C is not recommended.
Curie point: 55°C |
|
Note: These
specifications are subject to change without notice.
Back
to top
|